Free tool · DICOM

DICOM tag viewer and anonymizer

Drop in a .dcm file to read its header: every tag, VR and value, nested sequences included. Preview the image, then download a copy with common identifying tags removed.

  • Files never leave your device
  • Works offline once loaded
  • No sign-up, no limits
No file to hand?

How to read a DICOM header

A DICOM file is a list of attributes, each with a tag such as (0010,0010), a value representation (VR) that says what kind of value it holds, such as PN for a person's name or DA for a date, and the value itself. The first number of the tag is the group: 0002 is the file header, 0008 describes the study and instance, 0010 is the patient, 0020 holds the study and series identifiers, 0028 describes the image, and 7FE0 is the pixel data. Tags with an odd group number are private, defined by the vendor rather than the standard.

The viewer names each standard tag, shows dates, ages and UIDs in readable form, and lets you open sequences (SQ) to see the items inside. Use the filter to find a tag by number, name or value, or tick "Only tags that anonymizing changes" to see exactly what is identifying in the file.

How to anonymize a DICOM file

  1. Drop the file onto the box above, or click it to choose a file.
  2. Check the Anonymized column: it shows what will be removed, emptied or replaced.
  3. Pick what to keep. Dates, descriptions and demographics are removed by default; keep them if your research or support case needs them.
  4. Click Anonymize & download, then Inspect the anonymized copy to check the result.

The pixel data is copied unchanged, so the image is exactly as it was, including any text burned into it. The file also gets a note of the de-identification method used.

Frequently asked questions

Is my DICOM file uploaded anywhere?

No. The file is read and anonymized by JavaScript in your browser tab and nothing is sent to a server. You can check this by disconnecting from the internet after the page loads; the tool still works. You are still responsible for having permission to handle any patient data you open, so use test or synthetic studies where you can.

What does the anonymizer remove?

It applies part of the DICOM Basic Application Level Confidentiality Profile (PS3.15 Annex E) to a fixed list of common attributes: patient name and ID are replaced, birth date, accession number and referring physician are emptied, and addresses, phone numbers, other IDs, institution, operator and physician names, station name, device serial number and comments are removed. Private vendor tags are removed by default, and study, series and instance UIDs are replaced.

Will the anonymized files from one study still belong together?

Yes. New UIDs are derived from the original ones with a random key that lasts for your visit, so every file from the same study or series gets the same new study and series UID. Anonymize all the files of a study in one visit to keep them linked.

Does it remove names burned into the image?

No. Some ultrasound, secondary capture and scanned images have patient details drawn into the pixels. Tag anonymizing can't change that, and the tool warns you when an image is likely to have them. Check the preview before sharing.

Which DICOM files can it open?

Any DICOM Part 10 file in implicit or explicit VR little endian or explicit VR big endian, including files with nested sequences and compressed (JPEG, JPEG 2000, JPEG-LS, RLE) pixel data. It can also open a bare dataset with no file header. Deflated files are not supported yet. The image preview covers uncompressed grayscale and 8-bit colour images; for compressed images you still see and anonymize every tag.

Is this enough for HIPAA, GDPR or DPDP Act de-identification?

No. It is a convenience tool for developers, not a validated or certified de-identification service, and using it does not make a file compliant with HIPAA, GDPR, India's DPDP Act or any other law, or make sharing it lawful. It covers only the attributes listed above; burned-in pixel text, free text such as structured report content, and attributes not on its list are kept. Always review the output, and use a validated process for research, publication or data transfer.